Model |
TEDV-9000 |
TEDV-12000 |
TEDV-16000 |
TEDV-20000 |
Performance Parameters |
Sine Force (Peak) |
9000Kgf |
12000Kgf |
16000Kgf |
20000Kgf |
Random Force (rms) |
9000Kgf |
12000Kgf |
16000Kgf |
20000Kgf |
Shock Force |
18000Kgf |
24000Kgf |
32000Kgf |
40000Kgf |
Max Acceleration Bare
Table (Sine) |
100'g' |
100'g' |
100'g' |
100'g' |
System Velocity (Sine Peak) |
1. 8 m/s |
1. 8 m/s |
1. 8 m/s |
1. 8 m/s |
System Velocity (Shock Peak) |
2.4 m/s |
2.4 m/s |
2.4 m/s |
2.4 m/s |
Max Displacement
(peak to peak) |
51/76 mm |
51/76 mm |
51/76 mm |
51/76 mm |
Axial Resonance (+5%) |
1800 KHz |
1700 KHz |
1700 KHz |
1700 KHz |
Useful Frequency Range |
5 to 2000 Hz |
5 to 2000 Hz |
5 to 2000 Hz |
5 to 2000 Hz |
Shaker Parameters |
Mass of Armature |
90Kg |
120Kg |
160Kg |
200Kg |
Size of Armature (dia) |
460 mm |
590 mm |
600 mm |
600 mm |
Suspension Axial Stiffness |
8 kg/mm |
10 kg/mm |
10 kg/mm |
10 kg/mm |
Suspension Cross-Axial Stiffness |
2200 kg/mm |
3200 kg/mm |
3200 kg/mm |
3500 kg/mm |
Insert Pattern [M10 / M12J] |
Center - 1
200pcd - 8
400pcd - 8
|
Center - 1
200pcd - 8
400pcd - 8
550pcd - 8
|
Center - 1
200pcd - 8
400pcd - 8
550pcd - 8
|
Center - 1
200pcd - 8
400pcd - 8
550pcd - 8
|
Payload Capacity |
2000 Kg |
2000 Kg |
2000 Kg |
2000 Kg |
Stray magnetic field
(150mm above table) |
<1mT |
<1mT |
<1mT |
<1mT |
Cooling |
Water Cooling based system including st oring , circulating and cooling distilled water |
Shaker Mass |
8500 kgs |
11500 kgs |
15500 kgs |
19800 kgs |
Dimensions [mm] |
1800*1100*1350 |
1800*1200*1450 |
2000*1200*1550 |
2500*1350*1550 |
Utilities required |
6-7 bar compressed air, DM water, earthing |
Power Amplifier Characteristics |
THD (resistive Load) |
< 0.5% |
< 0.5% |
< 0.5% |
< 0.5% |
Signal to noise ratio |
> 75dB |
> 75dB |
> 75dB |
> 75dB |
Power efficiency |
> 92% |
> 92% |
> 92% |
> 92% |
Input Impedance |
10 Kohm |
10 Kohm |
10 Kohm |
10 Kohm |
Input sensitivity |
4Vrms, compatible with all standard controllers |
Power requirement
(13 Phase) |
220KVA |
300KVA |
400KVA |
500KVA |
Protection interlocks |
Over Current, Over Voltage, Under Voltage, Module Failure, Cooling
Interlock, Over Temperature Amplifier & Shaker, Current Limit, loss of
input phase etc |
Vibration Controller |
Standard Software |
Swept Sine, Random, Classical Shock, Resonance Search Track & Dwell |
Optional Software |
Random on Random, Sine on Random, Shock Response Spectrum,
Transient Time history etc |
No of Channels |
4 Channels upgradable upto 16 channels |